<br />Mitigation Strategy Report <br />FEMA-1134-DR-NC <br /> <br />State of North Carolina <br />Division of Emergency Management <br /> <br />to permanent structures, local communities who participate in the NFIP should regulate these former <br />vehicles in accordance with existing manufactured housing reguiations. However, when a community <br />is not participating in the NFIP, these requirements (10 not apply. Thus, the State should adopt specific <br />and comprehensive regulatory standards discouraging the instillation of RVs in parks, particularly in <br />SFHAs. Finally, consideration should be given to expanding current manufactured home park ordinances <br />to include RV parks, <br /> <br />. Unsecured Fuel Tanks & Air Conditioning Units <br /> <br />During Hurricanes Bertha and Fran, numerous propane tanks posed a potential hazard to communities. <br />Unanchored fuel tanks can break loose, tip over, or float and spill their hazardous contents. This may <br />cause fires and soil contamination, as well as damage structures they encounter while floating. Increased <br />damages can occur when tanks are driven by rapidly flowing waters along rivers or coastal surge <br />zones. Therefore, tanks should be anchored and filled to decrease flotation tendency. The appropriate <br />anchoring technique depends on tank size and the type of base or structure to which it is attached. EM <br />and tank suppliers should provide technical assistance to communities and businesses regarding <br />anchoring techniques and other safety features. Service valves should be turned off if the threat of <br />flooding is imminent. <br /> <br />I <br /> <br />I <br />I <br /> <br />The minimum floodplain management standards of the NFIP require that in new construction or <br />substantial improvements, all tanks must be "adequately anchored to prevent flotation, collapse, or <br />lateral movement of the structure resulting from hydrodynamic and hydrostatic loads." Structure is <br />defined in the regulations as, "including a gas or liquid storage tank, that is principally above ground." <br />The State Agriculture Department, responsible for propane tank placement permitting, should adopt <br />and enforce standards requiring all above ground tanks to be anchored and protected as required by <br />current flood prevention ordinances. <br /> <br />I <br />I <br />, <br />I <br />I <br />I <br /> <br />I <br />I <br />I <br />I <br />I <br /> <br />Unsecured air conditioning compressors and exposed electrical terminals experienced extensive <br />damage from winds and flooding, particularly along the coast. Most damaged structures had insufficiently <br />elevated air conditioning compressors. As required in new construction, all externally mounted air <br />conditioning compressors and other electrical devices should be elevated and secured to a level <br />above the BFE. A simple wood frame or concrete platform with suitable anchors can be constructed or <br />purchased for a relatively small sum of money. Moving or raising other utilities and electrical terminals <br />should be encouraged, particularly in SFHAs. <br /> <br />Fi~ure 13: Inappropriate and Appropriate Installation of Air Conditioning Units <br /> <br /> <br />I <br />I <br />I <br /> <br /> <br />I <br />I <br />I <br />I <br />L <br /> <br />Page 26 <br />