<br /> <br />a = Chassis I-beam spacing (in) <br />As discussed in Section B of Chapter IV, the following design conditions were used. <br />Rf = 20, 30 or 40 psf based on roof live load zone (figure 4.1) <br />Ar = Width (W) X length (L) (including eaves) <br />Df = 20 psf <br />Ff = 40 psf <br />Af = Width (W) X length (L) <br />h = 9.75 ft. <br />Wf = 15 or 25 psf based on wind load zone (Figure 4.2) <br />a = 75 1/2 in., 82 in., and 99 in. <br />s = 5, 6, 7, 8, 9, and 10 ft. <br /> <br />Pier Design <br />As presented in Section B of Chapter IV, various pier designs in Table 4.11 are recommended based <br />on the anticipated loads which impact the manufactured home and are transferred to the pier. The recom- <br />mended pier designs were determined using the interaction equation as follows: <br /> <br />fa + fb <br />1.33 = Fa Fb <br /> <br />Where: <br /> <br />fa = computed axial stress in psi <br />= [W x s x 60] -;- Ap <br />Where: <br />W = Outside width of manufactured home (ft) <br />s = Vertical member spacing (ft) <br />Ap = Cross sectional area of pier (in2) <br /> <br />fb = Horizontal loading in psi <br />= [Wf x h x s x f x 12] -;- Sx <br />Where: <br />Wf <br />h <br />s <br />Sx <br />f <br />= 0.20 f'm <br /> <br />= 0.30 f'm <br />Where: <br />f'm = Strength of concrete (psi) <br /> <br />The following design conditions were used in calculating the acceptable conditions under which pier <br />failure would not occur for the pier designs in Section B of Chapter IV. <br />W = 12 and 14 ft. <br /> <br />s = 5, 6, 7, 8, 9, and 10 ft. <br />We = 15 and 25 psf. <br /> <br />f'm = 1500 and 2500 psi. <br />f = 5,6,7,8,9,10,11,12,13, 14, and 15 ft. <br /> <br />Sx = Based on pier designs A-F <br /> <br />Ap = Based on pier designs A-F <br /> <br />Fa <br />Fb <br /> <br />= Lateral windload (psI) <br />= Outside height of manufactured home (ft) <br />= Vertical member spacing (ft) <br />= Section modulus of pier (in3) <br />= Length of pier (ft) <br /> <br />91 <br />