<br /> <br />Q/ / = Capacity parallel to grain (Ib) <br /> <br />e = Angle between horizontal and diagonal member <br /> <br />The total number of bolts and size required per connection are determined as follows: <br /> <br />Number bolts = W*f/Q <br /> <br />Having reviewed the methods and procedures utilized, one should appreciate the complexity of design <br />for elevated foundations. Where additional details are necessary, different conditions apply or further <br />design detail is required, publications such as those listed in Appendix A should be consulted. As noted <br />in the manual, state and local regulations should be considered to determine provisions requiring design <br />by a registered engineer. <br /> <br />97 <br />