Laserfiche WebLink
<br />When discharge is high enough to produce critical depth <br />equal to the crown of the culvert barrel, the full flow <br />condition shown in figure III-IB will occur. The outlet <br />velocity reduction is again illustrated in the previous <br />example. In this case, however, it is necessary to determine <br />if the increased culvert dimensions result in brink depth <br />below the culvert crown. When this occurs, the flow area <br />used in the continuity equation is that associated with <br />brink depth, which for this illustration is assumed to be <br />critical depth. Figures III-3 through 1II-8 are included <br />for convenience in determining critical depth for various <br />shapes of culverts. <br /> <br />Example: A 3.0-foot CMPdischarging 100 cfs, flowing full <br />with tailwater of 2.0 feet. <br /> <br />From Figure 1II-4 critical depth (de) exceeds 3.0 feet. <br /> <br />Therefore, the barrel is flowing full to the end. From table <br />1II-2 with d/D=l, A/D2=0.785 and V=100/.785(9)=14.15 fps. <br /> <br />Changing to a 4.0-foot CMP, changes dc to 3.1 feet which <br />is less than D so dc controls outlet velocity. <br /> <br />v = <br />FULL <br /> <br />100 = 7.98 and dc/D = 3.1 = .78 <br />.785(16) 4.0 <br /> <br />V/V = 1.16 from figure VII-C-3 and V = 1.16(7.98) = 9.25 <br />FULL <br /> <br />This is a reduction of about 35 percent instead of the <br />approximate 44 percent indicated in the previous example. <br /> <br />When culverts discharge as in figure III-IC and D with <br />critical depth near the outlet, changing the barrel slope will <br />have no effect on the outlet velocity as long as the slope is <br />less than critical slope. Changing the resistance factor <br />will change the depth at the outlet an insignificant degree <br />and will, therefore, not modify the outlet velocity. <br /> <br />The initial step is to compute normal depth (tailwater) in <br />the outlet channel, tables III-l and 2 at the end of this <br />section facilitates normal depth calculations with this, <br />Figures III-9 and 10 may be used directly to determine out- <br />let brink depths for rectangular and circular sections, <br />respectively. These figures are dimensionless rating curves <br /> <br />1II-2 <br /> <br />e <br /> <br />e <br /> <br />e <br /> <br />~ <br /> <br />