Laserfiche WebLink
<br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />of the hydrograph from CE 221 to obtain an inflow hydrograph to the lower portion of the BNRR <br />pond, Preparation of the EXTRAN inflow hydrographs is presented in Section A of the Technical <br />Addendum, <br />As previously described in Section 2,1, outlet facilities from the BNRR detention pond <br />consist of one 36-inch RCP and three 84-inch RCP's, The concrete inlet box which serves as the <br />entrance to the southern 84-inch RCP, to prevent low flows from entering the culvert, has an inlet <br />grate which is perched 9.4 feet above the minimum outlet elevation for the BNRR pond, Culvert <br />information and capacity calculations associated with the effective SWMM model are provided in <br />Section A of the Technical Addendum, <br />EXTRAN does not allow for the direct input of entrance and exit losses for culverts, <br />Consequently, culvert losses were considered by calculating an equivalent Manning's n value using <br />the following equation: <br /> <br />{ , (R(413)) } 1/2 <br />n, = n- + 29,L (ken/ranee + kexil) <br /> <br />where ne is the equivalent Manning's n, kenrmnce and kexu represent the entrance and exit loss <br />coefficients, n is the actual culvert Manning's n, L is the pipe length in feet, and R is the <br />hydraulic radius in feet. <br />The horizontal inlet grate which restricts inflows to the southern 84-inch RCP was analyzed <br />for the effective SWMM model as an orifice with an open area of 14 square feet and a discharge <br />coefficient (C) of 0,63, EXTRAN does not provide a straight forward method for analyzing a <br />drop (horizontal) orifice, when the drop orifice is elevated above the bottom of the associated <br />junction (in this case the minimum outlet elevation in the BNRR pond), Consequently, the inlet <br />grate was modeled as three small, perched orifices each with a diameter of 12 inches, The size <br />of each orifice was limited to 12 inches in order to keep the centroid of the modeled orifices to <br />within 6 inches of the actual inlet grate elevation, Consequently, the total open area of the three <br />equivalent orifices is 2,36 square feet. In order to compensate for the reduced area ofthe modeled <br />orifice opening, the discharge coefficient was adjusted to keep the product of C.A equivalent to <br />that indicated in the effective SWMM model calculations, The product of C'A for the SWMM <br />model was 8,82; the discharge coefficient for the EXTRAN model was initially set at 3,74 in order <br />to maintain the 8,82 value for C'A, <br />Initial modeling parameters used in EXTRAN were based solely on the physical <br />characteristics of the various facilities, Initial modeling results indicated a slightly lower water <br />surface elevation, and a correspondingly larger discharge than computed by the effective SWMM <br />model. Consequently, Manning's n values for the pipes were modified to provide better <br /> <br />15 <br /> <br />ANdERSON CONSulTiNG ENGiNEERS, 'NC. <br /> <br />T:'..QPEN\cocsrlDl "cocsrlOl fema-LO!'vIR !inal-t'Pt.\\pJ <br />