Laserfiche WebLink
<br />------, -- <br /> <br /> <br />Chapter VI: General Design Practices <br />Elevation <br /> <br />Elevation Sample Calculation <br /> <br />First Floor Ceiling: <br />Insulation - 16 inch of fiberglass <br />1/2 inch plywood <br />1/2 inch plaster and lath <br />Mise" heating, electrical, cabinets <br /> <br />8.0 psf <br />1.5 psf <br />10,Opsf <br />2.0 psf <br /> <br />Total <br /> <br />21.5 psf (lstFloorCeilin~ <br /> <br />First Floor: <br />Oak Floor <br />Subfloor - 3/4 inch plywood <br />Joists (2xI2) <br />Insulation - 10 inch fiberglass <br />Misc., piping, electrical <br />Gypsum ceiling - 1/2 inch <br /> <br />4,Opsf <br />3.0 psf <br />4.0psf <br />5.0 psf <br />3.0psf <br />2.5 psf <br /> <br />Total <br /> <br />21.5 psf (1 st Flom:) <br /> <br />Walls: <br />Interior - wood stud, plaster each side <br />Exterior - 2x4 @ 16 inches o,c., plaster <br />insulation, wood siding <br />Lower Level- 8 inch masonry, reinforcement <br />at 48 inches on center <br /> <br />20 psf <br /> <br />18 psf <br /> <br />50 psf <br /> <br />50144 <br /> <br />VI - E.50 <br /> <br />Engineering Principles and Practices of Retrofitting Flood-Prone Residential Structures <br />January 1995 <br />