FLOOD00591
CWCB
>
Floodplain Documents
>
Backfile
>
1-1000
>
FLOOD00591
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2009 1:21:41 PM
Creation date
10/4/2006 9:23:01 PM
Metadata
Fields
Template:
Floodplain Documents
County
Weld
Community
Greeley
Stream Name
Cache La Poudre River
Title
Floodplain and Floodway Analysis
Date
2/20/1994
Prepared For
CWCB
Prepared By
Brown & Caldwell
Floodplain - Doc Type
Floodplain Report/Masterplan
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
322
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />I"ull input and outputli,ting, along with files on di,kcLLe (i(aoailable! for each "fthe models Ibted below and <br />summary of the source of input parameters used in the models must be provided. The summary must include a <br />comolete description of any changes made from model to model (e.g. duplicate elfeclioe mode/to corrected e((ectwe <br />mode/). Only the Duplicate Effective and the Revised or Post-Project Conditions models must be submitted. See <br />instructions for directions on when other models may be required. Only the I DO-year flood profile is required for <br />SFII^s with a Zone A designation. For areas which do not have detailed flooding. a hydraulic model is not <br />required; bowever HFE's may not be added to the revised FIRM. <br /> <br />3. RIVERINE HYDRAULIC ANAL VSIS fORM <br />Models Submitted <br /> <br />!Xl Dupli"ate Effective Model <br /> <br />Copies of the hydraulic analysis used in the elTective FIS, referred to as the <br />elTective models 110-. 50-. 100-, and 500-year multi-profile runs and the <br />/1oodway run) must be obtained and then reproduced on the requestor's <br />equipment to produce the dUDlicate effective model. This is required to <br />assure that the effective model input data has been transferred correctly to <br />the requestor's equipment and to assure that the revised data will be <br />integrated into the effe"tive data to provide a continuous ~'IS model <br />upstream and downstream of the revised reach. <br /> <br />[Xl Corre"ted Effective Model <br /> <br />The corrected elTective model is the model that corrects any errors that <br />occur in the duolicate effective model. adds any additional cross sections to <br />the duolicate effective model, or incorporates more detailed topographic <br />information than that u,ed in the currently elTective model. The corrected <br />effective model must not reflect any man-made physical changes since the <br />date of the elTective model. An error could be a techni"al error in the <br />modeling pro"edures, or any construction in the floodplain that occurred <br />prior to the date of the effective model but was not incorporated into the <br />effective model. <br /> <br />!Xl <br /> <br />Existing or Pre-Proje"t Conditions Model <br /> <br />The duolicate effective or "orrected model is modified to produce the <br />existinll or ore-oroiect conditions model to reflect any modifications that <br />have occurred within the floodplain since the date of the effective model but <br />prior to the construction of the project for which the revision is being <br />requested. If no modification has occurred since the date of the elTective <br />model, then this model would be identical to the corrected effective or <br />duplicate effective Illodel. <br /> <br />o Revised or Po,t-I'roject Conditions Model N/ A <br /> <br />The existin\! or ore-oroiect conditions model (or duplicate e((ective or <br />corrected e((ective model, as appropriate) is revised to reflect revised or post- <br />project conditions. This model must incorporate any physical changes to <br />the floodplain since the effective model was produced as well as the elTects <br />of the project. When the request is for proposed project this model should <br />reflect proposed conditions. <br /> <br />o <br /> <br />Other: Please attach a sheet describing all other models or <br />calculations submitted. <br /> <br />I <br /> <br />I <br /> <br />I <br /> <br />I <br /> <br />:-Jatural <br /> <br />Floodway <br />!Xl <br /> <br />I <br /> <br />o <br /> <br />I <br /> <br />I <br /> <br />:-Jatural <br />o <br /> <br />r'loodway <br />!Xl <br /> <br />I <br /> <br />I <br /> <br />I <br /> <br />:-Jatural <br />o <br /> <br />I <br /> <br />~'Ioodway <br />o <br /> <br />I <br /> <br />I <br /> <br />Natural <br />o <br /> <br />I <br /> <br />~'Ioodway <br />o <br /> <br />I <br /> <br />I <br /> <br />Natural <br />o <br /> <br />Floodway <br />o <br /> <br />I <br /> <br />I <br /> <br />Rn,erme Hydraulic Analysl) "'Olm <br /> <br />I <br /> <br />t-orm4 <br /> <br />Pagelot I) <br />
The URL can be used to link to this page
Your browser does not support the video tag.