Laserfiche WebLink
<br />I <br />I <br />II <br />I <br />I <br />I <br />I <br />I <br />I <br />It <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />, <br />I <br /> <br />If <br /> <br />TECHNICAL MANUAL <br /> <br />FLOOD INFORMATION NEAR GAGED SITES ON THE SAME STREAM <br /> <br />Peak discharges at sites near gaging stations on the same stream can be <br />computed by the foJ lowing equation: <br /> <br /> <br />QT(U)= [:~r QT(G) <br /> <br />whe re <br /> <br />QT(U)= peak discharge at ungaged site for recurrence Interval T, <br /> <br /> <br />QT(G)= weighted average discharge at gaged site for recurrence interval T, <br /> <br /> <br />AU = drainage area at ungaged site, <br /> <br /> <br />AG = drainage area at gaged site, and <br /> <br /> <br />X = exponent for each flood region as follows: <br /> <br />F1 ood Reg i on <br /> <br />Plains <br />Mountains <br />Northern Plateau <br />Southern Plateau <br /> <br />Exponent, X <br />0.48 <br />.79 <br />.50 <br />.71 <br /> <br />The above procedure Is applicable for ungaged sites where the drainage area <br />ratio lies between 0.5 and 2.0. <br /> <br />\ <br />