Laserfiche WebLink
<br />) <br /> <br />) <br /> <br />responsible for all such training and for all activities of the <br />operators concerning the operation of the generators. <br /> <br />Seedinq Medium <br /> <br />Each generator will be attached to a propane tank. A 2 <br />percent solution of silver iodide and ammonium iodide in <br />acetone will be burned in a propane flame. Each generator will <br />emit not more than 20 grams of silver iodide per hour of <br />operation. <br /> <br />It will be the permittee's responsibility to ensure the <br /> <br />accurate calibration of each generator. In addition. the <br /> <br />permittee shall be responsible for keeping complete records of <br /> <br />the amount of silver iodide emitted per hour of operation for <br /> <br />each generator. <br /> <br />Seedinq Criteria <br /> <br />All pertinent storm characteristics shall be monitored by <br /> <br /> <br />the permittee to determine whether a storm. or a portion of a <br /> <br /> <br />storm. is to be seeded. Characteristics which shall be <br /> <br /> <br />considered shall include. but not be limited to. cloud top <br />temperature, lower-level atmospheric stability. height of cloud <br />base. and air mass temperature, The permittee shall be <br />responsible for considering any other characteristics which <br /> <br />-2- <br />