My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PUB00077
CWCB
>
Publications
>
Backfile
>
PUB00077
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2010 3:55:22 PM
Creation date
9/30/2006 10:14:26 PM
Metadata
Fields
Template:
Publications
Year
1987
Title
Construction Fund Annual Report 1987
CWCB Section
Finance
Author
CWCB
Description
Construction Fund Annual Report 1987
Publications - Doc Type
CF Annual Report
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />. <br /> <br />Colorado Water Conservation Board <br />1313 Sherman Street. Room 721 <br />Denver. Colorado 80203 <br /> <br />Twin Lakes Reservoir Project <br />(city of Greeley) <br /> <br />Introduction <br /> <br />Twin Lakes Reservoir is one of several high elevation <br />storage units owned by the City of Greeley. It is located in <br />Larimer County about nine miles south of Rustic. The dam for <br />this reservoir is 35 feet in height and has a crest length of <br />220 feet. It was constructed in the early 1900s by an unknown <br />group of investors. The reservoir has a decreed storage <br />capacity of 460 acre-feet. but at the normal maximum water <br />surface elevation it can currently store only 268 acre-feet. <br /> <br />Problem <br /> <br />. <br /> <br />On January 22. 1986. the State Engineer restricted the <br />storage in this reservoir to zero capacity due to the <br />deteriorated condition of the outlet works and excessive <br />embankment seepage. As this restriction will remain until <br />steps are taken to correct these problems. the city had a <br />feasibility study prepared to address these matters. This <br />study was performed by MOrrision-Knudsen Engineers. Inc.. of <br />Denver. and is the basis for the recommendation on this project. <br /> <br />Proposed Proiect <br /> <br />The alternative selected by the engineering consultant from <br />among four was to replace the existing dam spillway and outlet <br />works with a new roller-compacted concrete (RCC) dam and outlet <br />works to provide a 460 acre-foot reservoir. A new spillway <br />would be constructed within the RCC dam to pass the 100-year <br />flood. Higher intensity flooding events would overtop the dam. <br />but no eroding of the RCC would be expected. The estimated <br />cost of the proposed project is $825.000. <br /> <br />2338E <br /> <br />. <br />
The URL can be used to link to this page
Your browser does not support the video tag.