Laserfiche WebLink
<br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />TOW;-; OF )IQ:'(UME:\. - )\ui'"ICIPAL WELL #2 REPLACE)IF.;>;T PROJECT <br /> <br />.. <br />- <br /> <br />- <br /> <br /> <br />l\lunicipal \Vell #2 \\'ellllead <br /> <br />Proiect Description <br /> <br />The project consisted of complete fedrilling and pump replacement of an existing non- <br />gravel packed well. The existing well historically experienced sand pumping which resulted in <br />continued failure of the pump and appurtenances. <br /> <br />Proiect Data <br /> <br />Sponsor: TO\\TI of i\.lonument <br /> <br />Coun!)': EI Paso <br /> <br />Source: Denver Formation <br /> <br />Terms of Loan: 594.000 @. ..J.O% for 30 years <br /> <br />Suhstantial Completion: February I, 1995 <br /> <br />Design Engineer: JOM Halepaska & Associates. Inc. - Linleton. Colorado <br /> <br />Construction Contractor: Drillers: Layne Environmental Services - Denver, Colorado <br />Pumps: AmWest Well & Pump. Inc. - Henderson. Colorado <br /> <br />Desi~n Criteria: <br /> <br />Depth of Well = 950 feet <br />Pump size = 40 hp Ave. flow = 100 gpm <br />Adjudicated Capacity = 145 gpm <br /> <br />A.nnual Volume of 'Vater Delinred b~' the Project: 64 acre feet <br />