Laserfiche WebLink
<br />WATER USE ANALYSIS -- PERSONAL FIXTURE USE BASIS <br /> <br />BUILDING 200 <br /> <br />Toilets: (4.5 flushes/person/night X 1.67 gpf) = <br />Showers: (3.8 minutes/person/night X 1.75 gpm) = <br />Bathrm. sinks: (4 minutes/person/night Xl gpm) = <br />Kitch. sinks: (4 minutes/person/night X 1 gpm) = <br />Baths: (0.1 bath/person/night X 40 gallbath) = <br />Dishwasher: (0.08 loads/person/night X 10 gal/load) = <br />I TOTAL = <br /> <br />BUILDING 300 <br /> <br />7.5 <br />6.7 <br />4.0 <br />4.0 <br />4.0 <br />0.8 <br />27.0 gal/person/night <br />30.5 percent less than actual <br /> <br />Toilets: (5.5 flushes/person/night X 4.0 gpf) = <br />Showers: (4.4 minutes/person/night X 2.3 gpm) = <br />Bathrm. sinks: (4 minutes/person/night X 2 gpm) = <br />Kitch. sinks: (4 minutes/person/night X 2 gpm) = <br />Baths: (0.1 bath/person/night X 40 gal/bath) = <br />Dishwasher: (0.08 loads/person/night X 10 gal/load) = <br />I TOTAL = <br /> <br />22.0 <br />10.1 <br />8.0 <br />8.0 <br />4.0 <br />0.8 <br />52.9 gal/person/night <br />18.5 percent less than actual <br />