Laserfiche WebLink
<br />In 1995, Englewood treated an average of 6.5 MGD at its Allen water treatment plant This is <br />down from 7.8 MGD in 1991. Average annual water consumption by account in thousand <br />gallons is as follows: <br /> <br />Single Family <br />Multi Family <br />Mobile Home <br />Commercial <br />Industrial <br />Public <br /> <br />113.13 <br />620.86 <br />3482.00 <br />1258.371 <br />18200.44 <br />1798.01 <br /> <br />The estimated indoor water use was based on a study conducted by AquaSan in the older portion <br />of Westminster (pre-1977) which is similar to Englewood in demographics and physical <br />construction (lot size, home size, age, etc. ) and water usage (average single-family 113,000 <br />gallons). The Westminster study was conducted using data loggers on a statistically <br />representative sample population. The results of this analysis and the assumptions used by <br />Englewood in developing this conservation plan are as follows: <br /> <br />Residential per capita use in gallons summary: <br /> <br />Baths 5.73 <br />Showers 9.68 <br />Toilets 16.73 <br />Faucets 6.10 <br />Clothes Washers 16.09 <br />Dish Washers 0.89 <br />Cooling 6.93 <br />Leaks 0.48 <br /> <br />TOTAL 61.63 <br /> <br />The average number of residents per home is assumed to be 2.5 persons, with annual indoor-- - ' <br />water use being 50,200 gallons and outdoor 60,300 gallons and cooling 2,500 gallons. Total <br />single-family residential use is estimated as 1 13,000 gallons (.35 acre-feet) annually. <br />