Preliminary Design Memorandum <br /> Silt Pumping Plant Rehabilitation <br /> pumps are abruptly shut down and the control valves are closed in a timed <br /> operation. The flap valve at the end of the pipeline closes as soon as forward flow <br /> erodes and prevents water from the pump canal from flowing back into the <br /> discharge pipeline. But before the pump control valves are closed,the flow in the <br /> discharge lines is reported to reverse and spin the pump backwards. The pumps <br /> and motors are designed to spin backwards without damage. Current Reclamation <br /> designs typically include a pump control valve (often a motorized butterfly valve) <br /> and a check valve. The check valve closes at or just before flow reversal and <br /> prevents backflow from spinning the pump in reverse. A hydraulic transient study <br /> will be conducted in the design process to see which method is better for this <br /> particular project. <br /> Available Flow Rates for Individual and Combinations of Fixed-Speed <br /> Pumps <br /> Fixed-speed pumping can produce the following flow rates: <br /> • One small pump 3.4 cfs See Figure 2 <br /> • One medium pump 6.3 cfs See Figure 2 <br /> • One small, one medium pump 9.6 cfs See Figure 4 <br /> • One large pump 11.6 cfs See Figure 2 <br /> • One small, one large pump 14.7 cfs See Figure 5 <br /> • One medium and one large pump 17.4 cfs See Figure 6 <br /> • One small, one medium, one large pump 20.4 cfs See Figure 7 <br /> • One small,two large pumps 25.2 cfs See Figure 8 <br /> • One medium,two large pumps 27.6 cfs See Figure 9 <br /> • One small, one medium,two large pumps 30.0 cfs See Figure 2 <br /> All flow rates in between the above points cannot be achieved with fixed-speed <br /> pumping. Therefore, an intermediate flow point would dictate the use of the next <br /> larger pump size or combination. <br /> Available Flow Ranges for Variable Speed Pumps <br /> Number of VFDs needed for reliability and range: At least two VFDs are <br /> needed to provide a measure of redundancy. Adding VFDs to the two large pumps <br /> would allow the pumping plant to operate from about 3.2 to 30 cfs without any <br /> flow gaps within the range. See Figure 3 for the lower end of the flow range, <br /> Figure 10 for the mid-range and Figure 11 for the high end of the flow range. <br /> Interaction with system curve and efficiency variation over range: <br /> When the pump speed is reduced with a VFD,the pump curve revises in <br /> accordance to the affinity laws and a new intersection point of the pump curve <br /> and the system curve occurs.Note that the relative position of the operating point <br /> on the pump curve moves from right to left as the pump speed is reduced as <br /> 20 <br /> FOR OFFICIAL USE ONLY <br />