Laserfiche WebLink
D <br />C <br />B <br />5 <br />4 <br />+ SITE LAYOUT CONTROL POINTS (Autocod Model Coordinate System ) <br />NOTE. Add 220,000. feet to North and 1,300,000. feet to East forAutocod Model Coordinate Values — See Note 15 <br />Point <br />North <br />East <br />Description <br />Point <br />North <br />East <br />Description <br />CP -7 <br />4,515.27 <br />8,172.21 <br />Intake Structure Control Point <br />CP -46 <br />4,090.27 <br />7,995.22 <br />Fence Alignment Center Point <br />CP -2 <br />4,767.63 <br />8,120.34 <br />Intersect. Col. Lines e & 7 <br />CP -47 <br />Deleted <br />CP -4: <br />CP -41 3.983.09 <br />CP -3 <br />3,937.49 <br />8,08J.89 <br />Intersect. Col. Lines e & 18 <br />CP -48 <br />4,126.91 <br />8,294.99 <br />Fence Alignment PC <br />CP -4 <br />3,880.72 <br />8,075.27 <br />Air Chamber Center (See Note 16) <br />CP -49 <br />3,917.42 <br />8,320.70 <br />Fence Corner Point <br />CP -5 <br />3,779.29 <br />8,069.60 <br />Flow Meter Vault Center Point <br />CP -50 <br />3,907"35 <br />8 „736.93 <br />Fence Corner Point <br />CP -6 <br />4,178.70 <br />8,072.69 <br />Drain Inlet Center Point <br />CP -51 <br />3,685.20 <br />8,364.08 <br />Fence Comer Point <br />CP -7 <br />4,169.77 <br />8,193.02 <br />Culvert 2 Bend Center Point <br />CP -52 <br />3,683.14 <br />8,347,21 <br />Gate Post <br />CP -8 <br />4,276.42 <br />8,210.53 <br />Culvert 2 Outlet <br />CP -53 <br />3,679.75 <br />S. 319.42 <br />Gate Post <br />CP -9 <br />4.234.35 <br />8,220.41 <br />Culvert 7 Inlet <br />CP -54 <br />3,677.21 <br />8,298.64 <br />Fence Comer Point <br />CP -10 <br />4,343.73 <br />8,237.66 <br />Culvert 1 Outlet <br />CP -55 <br />3,735.89 <br />8,291.47 <br />Fence Alignment PC <br />CP -11 <br />Deleted <br />- _ �� _ <br />CP -56 <br />3,765.35 <br />8,263.04 <br />Fence Alignment PC <br />CP -12 <br />Deleted <br />CP -70 <br />CP -57 <br />3737.77 <br />8,257.72 <br />Fence Alignment Center Point <br />CP -13 <br />4.329.00 <br />8.15727 <br />Step Location Control Point <br />CP -58 <br />3,803.03 <br />8,025.13 <br />Fence Alignment PC <br />CP -14 <br />4,231.52 <br />8,141.24 <br />Povement Edge Center Point CP -59 <br />3,882.05 <br />8,037.64 <br />Fence Alignment Center Point <br />CP -15 <br />4,435.09 <br />8,094.75 <br />Pavement Edge PC CCP <br />-60 <br />3.894.56 <br />7,958.62 <br />Fence Alignment PC <br />CP -76 <br />4,402.73 <br />8.778.26 <br />Pavement Edge Center Point <br />CP -61 <br />3,852.25 <br />7,99749 <br />Pavement Edge Cen er Point <br />CP -77 <br />4,364.32 <br />8,10711 <br />Pavement Edge PC <br />CP -62 <br />3.848.68 <br />7,991.67 <br />Pavement Edge PC <br />CP -18 <br />4,292.29 <br />8,086.19 <br />Pavement Edge Center Point <br />CP -63 <br />J.623.43 <br />6,145.63 <br />Pavement Edge Center Point <br />CP- 79 <br />4,224.22 <br />8,117.66 <br />Pavement Edge PC <br />CP -64 <br />3,836.66 <br />8,158.02 <br />Pavement Edge Comer <br />CP -20 <br />4,172.02 <br />8,141.79 <br />Pavement Edge Center Point <br />CP -65 <br />3,915.74 <br />8,189.28 <br />C.O.D. Air Chamber Center Point <br />CP -21 <br />4,163.03 <br />8,198.58 <br />Pavement Edge PC <br />CP -66 <br />3,944.17 <br />8,192.26 <br />Crude Control Line <br />CP -22 <br />4,181.02 <br />8,085.00 <br />Pavement Edge PC <br />CP -67 <br />4,445.64 <br />8,110.64 <br />Cate Post <br />CP -23 <br />4,174.37 <br />8, 199.24 <br />Crude Control Line <br />CP -68 <br />4,443.51 <br />8.130.40 <br />Gate Post <br />CP -24 <br />4,169.52 <br />8,103.55 <br />Grade Control Line <br />CP -69 <br />4,440.57 <br />8,148.94 <br />Fence Comer Point <br />CP -25 <br />4,205.54 <br />8,095.07 <br />Grade Control Line <br />CP -70 <br />4,335.92 <br />8,224.98 <br />Fence Comer Point <br />CP -26 <br />3,913.96 <br />8,059.91 <br />Grade Control Line <br />CP -71 <br />4,337.65 <br />8,251.95 <br />Fence Corner Point <br />CP -27 <br />3,925.64 <br />8,082.01 <br />Grade Control Line <br />CP -72 <br />4,265.17 <br />8,247.42 <br />Fence Corner Point <br />CP -28 <br />3,895.90 <br />8,767.57 <br />Grade Control Line <br />CP -73 <br />4,329.80 <br />8,242.98 <br />Exterior Building Corner <br />CP -29 <br />3.875.72 <br />8,007.28 <br />Grade Control Line <br />CP -74 <br />4.313.23 <br />8,140.36 <br />Concrete Slab Corner <br />CP -30 <br />4.168.78 <br />8,081.09 <br />WAPA Yard Fence Comer <br />CP -75 <br />4,338.49 <br />8,170.87 <br />End of Line - Road Alignment <br />CP -31 <br />4,156.62 <br />8,081.13 <br />Segmental Wall Center Point <br />CP -76 <br />3,627.75 <br />8,280.38 <br />Culvert 3 Inlet <br />CP -32 <br />4,135.39 <br />8,077.77 <br />Segmental Wall Center Point <br />CP -77 <br />3.638.73 <br />8,365.32 <br />Culvert 3Outlet <br />CP -33 <br />4,153.97 <br />8,091.85 <br />WAPA Yard Fence Comer <br />CP -78 <br />CP -79 <br />4,176.17 <br />3,777.36 <br />8,120.73 <br />8.072.17 <br />Manhole Center Point <br />8” Pipe End <br />CP -34 <br />4,134.22 <br />8,088.72 <br />WAPA Yard Fence Corner <br />CP -80 <br />4,180.36 <br />8,111.87 <br />B" Pipe Bend Center Point <br />CP -35 <br />4,126.73 <br />8,078.42 <br />WAPA Yard Fence Corner <br />CP -81 <br />4,787.07 <br />7,992.87 <br />8" Pipe Bend Center Point <br />CP -36 <br />4,09D.OB <br />8,072.62 <br />WAPA Yard Fence Comer <br />CP -82 <br />4,162.62 <br />7226 86 <br />Crade Control Line <br />3 <br />CP -48` e <br />7,308.250.00 <br />CP -37 4,082.05 <br />NOTES <br />Segmental Wall Center Point <br />1. For alignment of access roods see drawing 69 -D -13 <br />See Part <br />2. For details of segmental retaining walls and concrett <br />Plan 2 <br />3. — Indicates fence post otigment. <br />(1130) <br />4. PC - PT Indicates Point of Curvature - Point or Tat <br />WAPA Yard Fence Comer <br />WAPA Yard Fence Comer <br />S. Ground to grid correction of 0.9996701 has not been <br />A <br />site layout control points shown in table, <br />6. CP -4 is control point for site layout. <br />CP -40 3,994.64 <br />, <br />i <br />Segmental Wall Center Point <br />X06 <br />/y10 °N <br />CP -4: <br />CP -41 3.983.09 <br />8,057.68 <br />WAPA Yard Fence Comer <br />CP -48` e <br />7,308.250.00 <br />CP -37 4,082.05 <br />8.069.32 <br />Segmental Wall Center Point <br />1 <br />CP -38 4,079.78 <br />CP -39 3,993.85 <br />8,080.10 <br />8.066.49 <br />WAPA Yard Fence Comer <br />WAPA Yard Fence Comer <br />A <br />z Z (7 r 1a) <br />CP -40 3,994.64 <br />8,055.48 <br />Segmental Wall Center Point <br />67.30 <br />/y10 °N <br />f} <br />CP -41 3.983.09 <br />8,057.68 <br />WAPA Yard Fence Comer <br />o <br />o <br />CP -42 3,982.39 <br />8,024.17 <br />Pavement Edge Comer Point <br />CP -73 <br />CP -43 $991.55 <br />7,998.19 <br />WAPA Yard Cate Post <br />f p =19.0319° CP -82 <br />° CP <br />CP -44 3,994,99 <br />7,976.56 <br />WAPA Yard Gate Post CP -71 <br />R =302.00 <br />- � - <br />CP -45 4,180.99 <br />8.003.99 <br />WAPA Yard Fence Comer <br />� <br />CP -72 <br />L= 754.04' <br />c <br />n <br />N <br />CP -10 <br />CP -74 <br />- _ �� _ <br />CP -9 CP -23 — CP-27 1 <br />-- — - - -� <br />CP -70 <br />_/ -- <br />r <br />— <br />CP -8 <br />CP <br />7 <br />1 <br />Z <br />See Part % <br />`20 <br />,/ See Part <br />1 1 <br />D U R A N G O PUMPING <br />P L A <br />Plan 1 <br />Plan 4 (1130) 6= 780,00° 1 <br />1 <br />(1130) <br />R =57,50 <br />5.00 L= 780.64' <br />CP -/S <br />12 <br />CP - 14 <br />1 <br />0 <br />`1 ,! <br />/ CP- 7 x <br />(7 7sJ) <br />R2.00 i I <br />PC-2 <br />CP <br />/ <br />1 Z <br />e <br />.00 <br />-1 <br />y / <br />6=1J8.9945* o° <br />CP -19 CP -80 <br />CP -78 <br />m <br />r <br />CP -69 i <br />R =75.00 <br />CP -24 <br />p <br />m <br />;t CP- 68�C/CP- <br />CP_ 16 <br />C= 787.94' <br />CP -25 <br />CP 37 <br />CP -38 <br />3 } <br />CP -39 <br />[ <br />a <br />/ CP -17 <br />` <br />�' ` <br />CP -37 <br />(1132) <br />CP -40 <br />C, <br />Cu <br />CP -67 r �� <br />(7733) <br />CP -301 <br />CP 6 <br />CP <br />CP -36 <br />N <br />° <br />Cp_ 18 <br />1 <br />CP -32 <br />y35 <br />\ <br />^' <br />