Laserfiche WebLink
Boulder White Rock Ditch and Reservoir Company <br />Updated November 20, 2008 <br />Page 3 of 5 <br />Table 1 <br />Water Rights <br />Agenda Item 26f <br /> <br />Name <br />Amount Adjudication <br />Date Appropriation <br />Date Decreed <br />Use Water <br />Source <br />Direct Flow <br />Decree 135 cfs June 2, 1882 November 1, 1873 Irrigation Boulder Creek <br />Direct Flow <br />Decree 26 cfs May 3, 1892 December 1, 1873 Irrigation Goose Creek <br />Panama #1 4,989 AF June 21, 1926 May 31, 1904 Irrigation Boulder Creek <br />Panama Refill 4,989 AF September 28, 1953 December 31, 1929 Irrigation Boulder Creek <br />Six Mile 958 AF December 19, 1900 August 20, 1894 Irrigation Boulder Creek <br />Six Mile Refill 958 AF September 28, 1953 December 31, 1929 Irrigation Boulder Creek <br />Project Description <br />A range of alternatives were considered: 1) Take no action; 2) Develop an internal exchange; and 3) <br />Build a pump station at the Panama Reservoir outlet. <br />Alternative 1- No Action: If no action is taken, the Company will not be able to meet the present <br />and future needs of its shareholders. As development continues below the reservoir, the exchanges <br />at the Boulder headgate will be further reduced, causing further delivery problems for the <br />Company. This alternative is not a viable option for the Company. <br />Alternative 2- Developing an internal exchange: The Company considered developing an internal <br />exchange of water between its own users. This option did not allow the flexibility to deliver water <br />to shareholders nor did it address accessing the 2,600 AF at the bottom of Panama Reservoir. <br />Alternative 3 -Pump Station: This option supplies water to the Company's North Branch Ditch <br />and the Upper Lateral Ditch, both located upstream of Panama Reservoir. The project consists of <br />three main components including a pump station with a reservoir intake pipe, and two separate <br />pipelines to supply the irrigation ditches. <br />Selected Alternative: The Company has chosen Alternative 3: <br />The pump station and reservoir water intake system will be located along the northern edge of <br />Panama Reservoir. The pump station supply system will consist of a concrete intake structure with <br />three intake screens and a 300-foot 36-inch reinforced concrete pipe from the intake structure to the <br />pump station wet well. Four pumps will extend into the wet well below the pump room. Two <br />pumps will be dedicated to the Company's North Branch Ditch pipeline and two pumps will be <br />dedicated to its Upper Lateral pipeline. <br />