Laserfiche WebLink
<br />Northeast Quadrant Study - Future Baseline <br /> <br /> <br />. The following pages contain graphs and tables portraying "future baseline" conditions <br />developed using output from Denver's P ACSM model for its Baseline NT scenario, <br />along with other sources as summarized below. The "future baseline" is intended to <br />represent "probable future" operations of individual systems without any particular <br />cooperative arrangements. . Future baseline data were. used to estimate the remaining <br />exchange potential, the utilization of reusable effluent, and the availability of reusable or <br />free river water at the Burlington headgate. The following tables and graphs are <br />included: <br /> <br />· South Platte Flow Above the Burlington Headgate - Thetable contains average daily <br />values by month, while the chart following is a plot of the daily data. These data <br />come directly from P ACSM. <br /> <br />· South Platte Below Burlington - The table contains average daily flow values by <br />month, while the chart following is a plot of the daily data. <br /> <br />· Metro Wastewater into Burlington - The table contains the average daily flow (cfs) <br />values. <br /> <br />· Free River at Burlington - The table contains the total monthly volume of "free river" <br />available at the Burlington headgate. Ifflows at the Henderson gage exceeded 550 <br />cfs, the water below the Burlington headgate was free. The chart that follows, is a <br />plot of the free river daily flow at the Burlington. <br /> <br />· Exchange Potential From Metro to Spinney-The minimum of the flow between the <br />exchange point and the diversion point was used to determine the exchange potential. <br />If the minimum flow between these two points was less than 10 cfs the exchange <br />potential was considered to be zero. <br /> <br />· Exchange Potential From Metro to Strontia- The minimum of the flow between the <br />exchange point and the diversion point was used to determine the exchange potential. <br />If the minimum flow between these two points was less than 10 cfs the exchange <br />potential was considered to be zero. <br /> <br />· Exchange Potential From Metro to Chatfleld- The minimum of the flow between the <br />exchange point and the diversion point was used to determine the exchange potential. <br />If the minimum flow between these two points was less than 10 cfs the exchange <br />potential was considered to be zero. <br /> <br />· Exchange Potential From Metro to Burlington-The minimum of the flow between <br />the exchange point and the diversion point was used to determine the exchange <br />potential. If the minimum flow between these two points was less than 10 cfs the <br />exchange potential was considered to be zero. <br />