My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
C150104 Feasibility Study
CWCB
>
Loan Projects
>
DayForward
>
0001-1000
>
C150104 Feasibility Study
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2011 10:05:51 AM
Creation date
3/4/2008 10:37:41 AM
Metadata
Fields
Template:
Loan Projects
Contract/PO #
C150104
Contractor Name
Groundwater Appropriators of the South Platte
Contract Type
Grant
Water District
0
Loan Projects - Doc Type
Feasibility Study
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />II. Project Parameters <br /> <br />A. Site Hydrology <br />The size of the impoundment will make this structure a jurisdictional dam regulated by the State <br />Engineer. The designation as a jurisdictional dam will require addressing such issues as dam hazard <br />classification and probable maximum flood criteria. The location of the project is in an area where it <br />is highly probable the dam will be classified as a Class 3 low hazard structure. This classification is <br />given for sites where there is a low probability for loss of life or damage to property. <br /> <br />The reservoir site is off channel and therefore does not intercept any major drainage basin. The <br />proposed design using a ring dike will prohibit any upstream drainage from entering the reservoir. <br />This will greatly reduce the size requirements for the spillway, which will result in cost savings. The <br />flood criteria for the South Platte River would likely show that failure of this structure would have <br />minimal impacts downstream. <br /> <br />B. Water Diversions/Delivery <br />There are two options that were explored for the delivery of water from the South Platte River to the <br />proposed reservoir site. The Peterson Ditch is a left bank diversion from the South Platte River that <br />passes to the north of the proposed reservoir site. The Peterson Ditch has the option of diverting <br />flows directly from the river or being supplied from three high capacity wells owned by GASP, <br />which are located near the diversion structure. The Peterson Ditch is owned and operated by the <br />Jules burg Irrigation District. A new structure to release water from the ditch would be installed near <br />the northeast comer of the reservoir. This structure would have a capacity in the range of20 to 40 <br />cfs depending on final project configuration. It is anticipated that a carriage charge will be required <br />by the Jules berg Irrigation District for the use of their stru<;ture. The typical charge runs around $4 <br />per acre-foot based on other users that have agreements with the ditch company. <br /> <br />The Peterson Ditch is an earthen channel structure that passes just to the north of the proposed <br />reservoir site. A preliminary survey investigation indicated that there is a sufficient change in <br />elevation between the ditch and the reservoir to allow for gravity diversions from the Peterson Ditch. <br />Based on a preliminary survey of the Peterson Ditch and the reservoir area, gravity diversions from <br />the ditch can be utilized to efficiently fill the reservoir to a stage approximately 2-3 feet below the <br />high water line. The preliminary layout of the reservoir has a high water line at an elevation of 3,566 <br />and a storage capacity of 2,229 acre-feet. The gravity diversions from the Peterson Ditch would be <br />capable of filling approximately 1,700 acre-feet. The remaining storage in the reservoir, <br />approximately 500 acre-feet, will need to be filled from tht:: "Ovid Wells" or another source with <br />adequate head. <br /> <br />A conversation with the operator of the Peterson Ditch revealed no apparent conflicts if the ditch was <br />utilized for a winter fill of the reservoir. The only other diversion below the proposed project, that is <br />active during the winter period, is the diversion for the Lower South Platte Recharge project. The <br />Lower South Platte Recharge site is capable of diverting 30-40 cfs (limited by the capacity of the <br />recharge site). <br /> <br />The operating capacity of the Peterson Ditch, according to the ditch rider, is approximately 90 cfs. <br />The ditch rider indicated that the limiting factor for ditch capacity is bank erosion in the <br />steeper sections of the ditch near the headgate. The capacity of the ditch increases above the <br />proposed release structure. There are several inflow points upstream that capture stormwater which <br />flows down the ditch. There may be some opportunity to divert these stormwater flows if water <br />quality and administration issues can be adequately addressed. <br /> <br /> <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.