Laserfiche WebLink
Identified Projects <br />Identified Projects and Processes <br />and Processes <br />for Meeting Future M&I Water <br />Demands <br />•Failure to implement identified projects and <br />processes will increase the pressure to transfer <br />agricultural water supplies <br />–Firming the yield of ag transfers for M&I use <br />requires storage <br />•Conservation will play a significant role and is <br />built into future plans <br />5 <br />Identified Projects <br />and Processes <br />Conservation Table Describing Levels <br />Percent Reduction in Future M&I Demand <br />Level Types of Programs 2000 2010 2020 2030 <br />I Plumbing codes n/a* (passive savings reduction only) <br />Fixture standards from National Energy Policy Act <br />II Metering n/a* 3% 4% 5% <br />Leak detection <br />III All of the above (Level II) n/a* 5% 8% 10% <br />Education <br />Rebates for toilets and washers <br />Audits: residential and commercial <br />Landscape audits <br />Increasing rate structure <br />IV All of the above (Level III) n/a* 10% 15% 20% <br />Steep pricing rate and surcharges <br />Rebate for landscape changes <br />Turf replacement & restrictions <br />Rebates for irrigation sensors & controllers <br />Sub-metering of master-meter properties <br />Fixture retrofit upon sale of property <br />Ordinance eliminating single-pass cooling <br />6 <br />DRAFT <br />3 <br />